SPECIFICATIONS
serial teChnology
Data Rate 115.2 kbps maximum
rs-232
Connector DB25 female (DTE)
Connector DB25 male (DCE)
Signals TD, RD, RTS, CTS
Transmission Mode Asynchronous, half or full duplex, point-to-point
Power
Source Port-powered from RS-232 data and handshake lines
Optional External
Source
+10 to +16 VDC @ 40 mA max
External Connections
2.5mm power jacks (tip positive) or
DB25 connectors pins 11 (+) and 12 (-)
isolation
Volts/Duration
4,000 Volts RMS isolation for 1 minute
(may be limited by external supply)
MeChaniCal
Dimensions 10.4 x 5.8 x 2.4 cm (4.1 x 2.3 x 0.95 in)
Minimum Air
Clearance between
DTE & DCE Sides:
5 mm (0.197 in)
Minimum Creepage
Distance between
DTE & DCE Sides:
8 mm (0.315 in)
environMental
Operating
Temperature
0to+70°C
Storage Temperature -55°to125°C
Operating Humidity 10 to 90% Non-Condensing
MTBF 351896
MTBF Calc. Method Parts Count Reliability Prediction
aPProvals / CertiFiCations - 232sPhi4
FCC Part 15, CISPR, EN 55022: 2010 + AC:2011 Class B Emissions
CE
IEC 60601-1-2:2007 Medical Electrical Equipment, Electromagnetic Compatibility
EN 61000-6-1: 2007 Generic Standards for Residential, Commercial and Light-
Industrial Environments
EN 61000-4-2: 2009 Electro-Static Discharge (ESD)
EN 61000-4-3: 2006 +A1 +A2 +IS1 Radiated Field Immunity (RFI)
EN 61000-4-4: 2012 Electrical Fast Transients-Burst Immunity (EFT)
Download complete Declaration of Conformity at www.bb.elec.com
4kV RS-232 Optical Isolator
232SPHI4
The 232SPHI4 isolates and protects RS-232 equipment from lightning
surges, accidental high voltage shorts, and ground loops. RS-232 data
signals at up to 115.2K bps as well as the RTS and CTS handshake lines
are supported. The 232SPHI4 provides 4000 Volts of isolation between
sides, and maintains creepage and air clearances required for double or
reinforced insulation by IEC 60601-1.
Model 232SPHI4 has 4000 Volts of isolation — twice the rating of most
isolators — to protect RS-232 equipment from lightning strikes, accidental
high voltage shorts and ground loops.
DTE device connections are made through a DB-25 female. DCE device
connections are made through a DB-25 male. The two sides of the isolator
are powered independently to maintain isolation. Both sides can draw
power from the RS-232 data and handshake lines, eliminating external
powering requirements in nearly all systems.
If the isolator is to be used with low power ports or when no handshake
lines are available, external power can be supplied to either side. This
versatile powering configuration minimizes the number of supplies
required by the overall system.
• 4,000V,2-wayopticalisolation
• DB25maleandDB25femaleconnectors
• Canbeusedin60601-1applications
• Port-poweredORuseoptionalexternalpowersupply
PRODUCT FEATURES
ORDERING INFORMATION
Model
nuMber
Channels
ProteCted
dte
ConneCtor
dCe
ConneCtor
isolation
232SPHI4 4 DB25 Female DB25 Male 4,000 V
ACCESSORIES
232PS2 - 12VDC@100mA wall transformer power supply, tinned stripped leads
PS1EU-1000 - 220-240 VAC to 12 VDC Power Supply, jack, Euro CEE7/7 plug
PS1UK-1000 - 220-240 VAC to 12 VDC wall power supply, jack, UK BS-1363 plug
232CAMR - DB9 Male to DB25 Female, 6 in (15.2 cm)
232CAMS - DB9 Female to DB25 Male, 6 in (15.2 cm)
232SPHI4_3713ds
Page view 0
1

Summary of Contents

Page 1 - 4kV RS-232 Optical Isolator

International Office: 707 Dayton Road PO Box 1040 Ottawa, IL 61350 USA 815-433-5100 Fax 433-5104 European Office: Westlink Commercial Park Oranmor

Comments to this Manuals

No comments