Set The 422/485 Side of Converter
Connect Your RS232 Device
(Terminal Block OR DB9 Port)
Computer
Termination Switch: Set to OFF (Recommended)
Switch 5
If you want to enable termination,
refer to: http://www.bb-elec.com/
485LDRC9
Set the Dipswitch Settings for Baud Rate
For baud rates not listed above refer to:
http://www.bb-elec.com/485LDRC9
Additional tech notes on RS232 DTE DCE connections
are located at: http://www.bb-elec.com/tech/DTE-DCE
Loopback Test (Optional)
To verify serial port and 485LDRC9 functionality
• Congure for RS-485 four wire,
9600 baud.
• Jumper terminals H to L and G to K.
• Connect a PC to the RS-232 port
(see Step 1).
• Using HyperTerminal or similar program,
connect to the appropriate COM port
(remember to set the baud rate at 9600).
Turn off HyperTerminal local echo.
• Start typing. If you can see the data
you are typing, you have a good loop-
back. If you cannot, contact tech support.
• LED Indicators: Power is ON when power
is applied. TD flashes when RS-422/485
data is sent. RD flashes when RS-422/485
data is received.
Set DIP
Switches to:
Your Device485LDRC9
Use a straight through DB9 to DB9 if you are
connecting to a computer (DTE).
Use a cross over (null modem) DB9 to DB9
if you are not connecting to a computer. (DCE)
Additional tech notes on 422/485 are located at:
http://www.bb-elec.com/485LDRC9
Product Overview
Terminal Block
Connectors
A – F
Terminal Block
Connectors
G – M
DB9 F PINS
DIP Switches
1 – 8
Top View
(232 and Power Side)
Bottom View
(422/485 Side)
Connect Your Power Supply
External Power
Supply
Terminal C:
(Ground/V (–)
Terminal F:
V (+)
Field Device
Your Device485LDRC9
Please Note:
Terminal block and DIP switch settings located on product.
2 Wire 485 4 Wire 485/422
Your Device Your Device485LDRC9 485LDRC9
DTE DCE
Converter uses 0.5 W
RS-485 4-Wire
G
K
DATA
B (+)
DATA
A (-)
GND
H
L
J
M
G
TDB (+)
TDA (-)
RDB (+)
RDA (-)
GND
K
H
L
J
M
D
TD
RD
A
E
B
F
C
GND
D
TD
RD
GND
A
E
B
F
C
L
K
H
G
1
2
3
4
5
6
7
8
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
SW-1 SW-2 SW-3 SW-4
RS-485 2-Wire Half Duplex
ON ON ON ON
RS-485 4-Wire Full Duplex
ON OFF OFF OFF
RS-422 Full Duplex
OFF OFF OFF OFF
SW-6 SW-7 SW-8 Timeout (MS)
2400
OFF OFF ON 4.16
4800
OFF ON OFF 2.08
9600
ON OFF OFF 1.04
19.2K
ON ON ON 0.580
Use the 120Ω
Built-in Termination
ON
Use External or
No Termination
OFF
2
1
5
4
3
6
Page view 0
1 2 3

Summary of Contents

Page 1 - Product Overview

Set The 422/485 Side of ConverterConnect Your RS232 Device (Terminal Block OR DB9 Port)ComputerTermination Switch: Set to OFF (Recommended)Switch 5If

Page 2 - 485LDRC9

TroubleshootingFast, Easy AnswersTiming Issues? (Usually applies when using 2-wire 485)The 485LDRC9 uses RC time constant. This means that when you ar

Page 3

UL Installation InformationUnderwriters Laboratories Conditions of Acceptability – When installed in the end-use equipment, consideration should be