SPECIFICATION
MODEL
DCVOLTAGE
RATEDCURRENT
CURRENTRANGE
RATEDPOWER
OUTPUT VOLTAGE ADJ.RANGE
LINEREGULATION
LOADREGULATION
SETUP,RISETIME
HOLDUP TIME (Typ.)
VOLTAGERANGE Note.6
FREQUENCY RANGE
EFFICIENCY (Typ.)
INPUT
INRUSHCURRENT (Typ.)
LEAKAGECURRENT
OVERTEMPERATURE
SAFETY STANDARDS
HARMONICCURRENT
EMSIMMUNITY
WORKINGTEMP. Note.5
WORKINGHUMIDITY
STORAGETEMP.,HUMIDITY
DCOKREALY CONTACTRATINGS(max.)
TEMP.COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVERVOLTAGE
ACCURRENT (Typ.)
800ms,150ms/400VAC 2000ms,150ms/230VACatfullload
18ms/400VAC atfullload16ms/230VAC
180~550VAC254~780VDC
47~63Hz
92%
1.6A/400VAC4A/230VAC
56~65V
93%
COLDSTAR50A
<3.5mA /530VAC
29~33V
Protectiontype:Shutdowno/pvoltage, auto-recoveryafter1minuteifthefaultconditionisremoved
95 5 (TSW)detectonheatsinkofpowerswitch
Protectiontype:Shutdowno/pvoltage,recoversautomaticallyaftertemperaturegoesdown
UL508approved,DesignrefertoGL
CompliancetoEN55022(CISPR22),EN61204-3ClassB
CompliancetoEN61000-3-2,-3
-30~+70 (Refertooutputloadderatingcurve)
60Vdc/0.3A,30Vdc/1A,30Vac/0.5A resistiveload
20~95%RHnon-condensing
-40~+85 ,10~95%RH
0.03%/ (0~50
Component:10~500Hz,2G10min./1cycle,60min.eachalongX, Y,Zaxes;Mounting:CompliancetoIEC60068-2-6
112.8Khrsmin.MIL-HDBK-217F(25 )
CompliancetoEN61000-4-2,3,4,5,6,8,11,ENV50204,EN55024,EN61000-6-2(EN50082-2),EN61204-3,heavyindustrylevel,criteria A approved
85.5*125.2*128.5mm(W*H*D)
1.7Kg;8pcs/14.6Kg/0.9CUFT
WDR-480-48
48V
10A
0~10A
480W
150mVp-p
48~55V
1.0%
0.5%
1.0%
WDR-480-24
24V
20A
0~20A
480W
100mVp-p
24~28V
1.0%
0.5%
1.0%
Features :
WDR-480 series
WITHSTANDVOLTAGE
ISOLATIONRESISTANCE
I/P-O/P:3KVACI/P-FG:1.5KVACO/P-FG:0.5KVAC O/P-DCOK:0.5KVAC
I/P-O/P,I/P-FG,O/P-FG:>100MOhms/500VDC/25 /70%RH
EMICONDUCTION&RADIATION
ENVIRONMENT
SAFETY &
FUNCTION
EMC
(Note4)
PROTECTION
RIPPLE&NOISE(max.) Note.2
VOLTAGETOLERANCE Note.3
1. All parameters NOT specially mentioned are measured at 400VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Installation clearances : 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded permanently with full power.
In case the adjacent device is a heat source, 15mm clearance is recommended.
6. Derating may be needed under low input voltage. Please check the derating curve for more details.
480WSingleOutputIndustrialDINRAIL PowerSupply
Single and two phase wide input range 180~550VAC
High efficiency 93% and low power dissipation
Protections: Short circuit / Overload / Over voltage / Over temperature
Cooling by free air convection
Can be installed on DIN rail TS-35/7.5 or 15
UL 508(industrial control equipment)approved
EN61000-6-2(EN50082-2) industrial immunity level
Built-in DC OK relay contact
100% full load burn-in test
3 years warranty
FileName:WDR-480-SPEC2010-09-06
105~130% ratedoutputpower
Protectiontype: Constantcurrentlimiting,unitwillshutdownafter3sec.,auto-recoveryafter1minuteifthefaultconditionisremoved
Page view 0
1 2 3

Summary of Contents

Page 1 - WDR-480 series

SPECIFICATIONMODELDCVOLTAGERATEDCURRENTCURRENTRANGERATEDPOWEROUTPUT VOLTAGE ADJ.RANGELINEREGULATIONLOADREGULATIONSETUP,RISETIMEHOLDUP TIME (

Page 2

FileName:WDR-480-SPEC2010-09-06MechanicalSpecificationCaseNo.984BUnit:mm+BlockDiagramDCOKRelayContactContactClose PSUturnson/DC

Page 3

AMBIENTTEMPERATURE( )LOAD(%)-30 0 10 20 30 40 50 60 7020406080100(VERTICAL)OutputderatingVSinputvoltageDeratingCurveFileName:WDR-480-SPEC2

Comments to this Manuals

No comments